Loading...

Accessories

 

Talking Display Unit

    

Input and Output Accessories

MIU - Multiple Input Unit

Allows up to 12 switches, sensors or PIR detectors to be connected to the TDU.  Each switch, sensor or PIR detector will have its own unique message output.

MULTIPLE INPUT UNIT will allow up to 12 separate sensors to be connected to the one TDU. The TDU can then play one of up to 12 separate messages, held in its memory, depending on which sensor has been triggered.

This means that:

Sensor 1 when triggered will cause Message 1 to play
Sensor 2 when triggered will cause Message 2 to play
.....and so on up to sensor number 12.

Sensors for use with the MIU can be 'normally open' or 'normally closed'. Please specify which type you are using at time of order.

Sensors can be located up to 100m from the MIU unit, or greater than 100m from the MIU if low resistance wiring is used. The remote sensors connect to the MIU via a female 25 pin D type connector. Each sensor has been allocated a specific pin position (full connection details are provided in the MIU User Guide which can be downloaded by clicking the MIU image below and selecting the documentation tab).

While the TDU is playing a message, the MIU will continue to detect further triggering by the attached sensors and can hold in buffer up to 10 separate further triggers. Then when each message is complete, the MIU will instruct the TDU to play the message corresponding to the next triggering action. The TDU can only play one message at one time.

Communication between the MIU and the TDU is achieved via a single 2 pair telephone cable, which is supplied with the MIU. There is no need for any other external connections.
 

3 Models are available :

MIU4 allows for connection of up to 4 switches or sensors 

MIU8 allows for connection of up to 4 switches or sensors 

MIU12 allows for connection of up to 4 switches or sensors 

 

MIU units can be used with :

    Normally Open Switches (-NO prefix), when standard switches are used.
or 
   Normally Closed Switches (-NC prefix), when security switches or sensors are used such as PIR detectors. 

 

SSU - Speaker Switching Unit

Allows up to 12 speakers (4 Ohm or 8 Ohm) to be connected to the audio output of TDU, when used in conjunction with the Multiple Input Unit. This complete system then provides for 12 independent and separate "zones" each with its own message and local speaker.

SPEAKER SWITCHING UNIT, which is designed to operate with the MIU and the TDU, will also allow up to 12 separate 8 ohm speakers to be connected to the one Talking Display Unit (TDU), in conjunction with up to 12 separate sensors. This complete system then provides for 12 independent and separate "zones" each with its own message and local speaker.


This means that:

Sensor 1 when triggered will cause Message 1 to play on speaker 1

Sensor 2 when triggered will cause Message 2 to play on speaker 2

Sensor 3 when triggered will cause Message 3 to play on speaker 3

....and so on up to speaker number 12

Speakers can be located up to 100m from the TDU unit, or greater than 100m from the TDU if low resistance wiring is used. The remote speakers connect to the SSU via a female 25 pin D type connector. Each speaker has been allocated a specific pin position (full connection details are provided in the SSU User Guide which can be downloaded by clicking the SSU image below and selecting the documentation tab).

Power for the SSU and communication between the SSU and the TDU is achieved via a single 2 pair telephone cable, which is supplied with the SSU. There is no need for any other external connections.

This complete system then provides for 12 independent and separate "zones" each with its own message and local speaker.

3 Models are available :

 

SSU4   allows for connection of up to 4 speakers

SSU8   allows for connection of up to 4 speakers

SSU12      allows for connection of up to 8 speakers

 

 

 


 
Audio Switching Unit

AU $199.00

   
MIU 12 Port Multiple Switch / 12 Trigger Input Unit

AU $229.00

MIU12 Allows up to 12 switches, sensors or PIR detectors to be connected to the TDU.  Each switch, sensor or PIR detector will have its own unique message output.

 

 
 
men_clothes.jpg Multiple Switch / 4 Trigger Input Unit

AU $169.00

MIU4 Allows up to 4 switches, sensors or PIR detectors to be connected to the TDU.  Each switch, sensor or PIR detector will have its own unique message output.

   
Multiple Switch / 8 Trigger Input Unit

AU $199.00

MIU8  Allows up to 8 switches, sensors or PIR detectors to be connected to the TDU.  Each switch, sensor or PIR detector will have its own unique message output.

 

 
 
Speaker Switching Unit - 12 Port Version

AU $229.00

SSU12 Allows up to 12 Separate Speaker Zones when used with MIU12. Each switch, sensor or PIR detector will have its own unique message output to its own unique Speaker.

   
tjpg Speaker Switching Unit - 4 Port Version

AU $169.00

SSU4 Allows up to 4 Separate Speaker Zones when used with MIU4. Each switch, sensor or PIR detector will have its own unique message output to its own unique Speaker.

 
 
Speaker Switching Unit - 8 Port Version

AU $199.00

SSU8 Allows up to 8 Separate Speaker Zones when used with MIU8. Each switch, sensor or PIR detector will have its own unique message output to its own unique Speaker.